{"product_id":"bianco-flexisolar-40-4-0kw-variable-speed-drive-controller-with-hybrid-ac-dc-convertor","title":"Bianco NXT FlexiSolar-40 Variable Speed Drive Pump Controller with Hybrid AC\/DC Convertor","description":"\u003ch1\u003eBianco FlexiSolar-40 4.0kW Variable Speed Drive Controller with Hybrid AC\/DC Convertor\u003c!----\u003e\n\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/files\/811612_500.pdf?v=1724123869\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eDOWNLOAD SPECIFICATIONS \u0026amp; USER MANUAL\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0007\/1702\/9439\/files\/811613_100.pdf?v=1744007138\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eDOWNLOAD PRODUCT SPECIFICATIONS \u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe NXT FLEXI-SOLAR pump controller is a variable speed drive designed for three-phase asynchronous motors and permanent magnet synchronous motors. The controller provides motor soft-start, speed control, fault detection and motor protection.\u003c\/p\u003e\n\u003cp\u003eThe incoming power source can be DC, AC or a combination of both. High-voltage DC power from a solar array is converted into AC power to drive the pump. When the solar energy drops, the controller can automatically switch to a backup AC power source, such as generator or battery storage In situations of poor power supply (low solar irradiation or ‘brown’ power) the controller adjusts to maintain the output voltage and decreases the pump speed to match the available energy, protecting the system components from harm.\u003c\/p\u003e\n\u003cp\u003eTypically, the NXT FLEXI-SOLAR pump controller will run when there is a demand for water and sufficient energy is available. When a water demand is detected, the controller slowly increases the motor speed while gradually increasing the motor voltage. The motor temperature and starting current of the solar water pump system are lower than DOL starting, extending the life expectancy of the motor.\u003c\/p\u003e\n\u003cp\u003ePerformance of the system is continuously monitored to detect abnormal conditions. In\u003cbr\u003emany cases, the controller will provide compensation as needed to maintain uninterrupted running of the system. If there is a possibility of equipment damage, NXT FLEXI-SOLAR will protect the system and display the fault status. Pumping will automatically resume after the fault cause is eliminated. \u003c\/p\u003e\n\u003ch3\u003eAPPLICATIONS\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOff-grid pumping\u003c\/li\u003e\n\u003cli\u003eCombining Solar DC and locally generated AC power to\u003cbr\u003ereduce running costs of ICE power generation\u003c\/li\u003e\n\u003cli\u003ePowering standard 3 phase pumps with asynchronous\u003cbr\u003emotors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFEATURES\u003c\/h3\u003e\n\u003cul class=\"list-ul\"\u003e\n\u003cli\u003eOptimised pump performance - Solar Maximum Power Point Tracking (MPPT}\u003c\/li\u003e\n\u003cli\u003eSoft start, low motor start current.\u003c\/li\u003e\n\u003cli\u003eMulti-pump control. 1 master and up to 5 auxiliary controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eIn-built Pump Protections:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller monitors the system and automatically shuts down when:\u003c\/p\u003e\n\u003cul class=\"list-ul\"\u003e\n\u003cli\u003eThe source water level is low\u003c\/li\u003e\n\u003cli\u003eThe destination is full and further water is not required\u003c\/li\u003e\n\u003cli\u003eThe pump is blocked or overloading.\u003c\/li\u003e\n\u003cli\u003eHigh voltage surge\u003c\/li\u003e\n\u003cli\u003eLow voltage input\u003c\/li\u003e\n\u003cli\u003eMotor phase loss\u003c\/li\u003e\n\u003cli\u003eShort circuit\u003c\/li\u003e\n\u003cli\u003eController internal over-temp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMORE FEATURES\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eController Overheating Monitoring\u003c\/strong\u003e\u003cbr\u003eThe controller is designed to run at full power up to ambient temperatures of 45°C. At\u003cbr\u003etemperatures above 45°C, the controller reduces the carrier frequency (switching frequency of IGBT) to maintain operation as much as possible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater level control \u003c\/strong\u003e\u003cbr\u003eTwo optional water level detection devices (switch or probe) can be connected to provide additional control of the pump. Installed at the source, this prevents the pump running without water present. A float switch or probe installed at the destination OR a pressure switch in the discharge line will prevent the pump from running when there is no water demand.\u003c\/p\u003e\n\u003ch3\u003eTECHNICAL SPECIFICATIONS\u003c\/h3\u003e\n\u003ctable class=\"content-table cv-table-1\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"cv-table-row-0\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eOutput kW\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-1\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eRated Current\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-2\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eAC Input Voltage Range (V)\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e280V-440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-3\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eOutput Voltage (+-15%)\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e3 Phase 380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-4\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eMax DC Voc\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-5\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eEffective Vmpp Voltage Range\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e440-750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-6\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eBest Working Vmpp Voltage\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e560V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"cv-table-row-7\"\u003e\n\u003ctd class=\"cv-table-cell-0\"\u003eNumber of DC Input Circuits\u003c\/td\u003e\n\u003ctd class=\"cv-table-cell-1\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e*A qualified electrician should correctly size and install circuit breakers to protect the power supply. The fitment of additional surge protection is recommended.\u003c\/p\u003e","brand":"Bianco","offers":[{"title":"Default Title","offer_id":67639465869681,"sku":"811613","price":1428.35,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1035\/2554\/8401\/files\/bianco-flexisolar-22-pump-controller_dc6cc081-57bb-42da-8db5-320b9587a6f3.jpg?v=1791209077","url":"https:\/\/solar.landwater.com.au\/products\/bianco-flexisolar-40-4-0kw-variable-speed-drive-controller-with-hybrid-ac-dc-convertor","provider":"Land \u0026 Water Technology - Solar Pumps","version":"1.0","type":"link"}